Residual Current Circuit Breaker With Overload Protection CJBL-63 4P

Type and specification CJ: Company code B: MCB L/F: L-Electronic type/F-Electromagnetic type 40/63: 6~63A(6KA)/6~40A(10KA)/Casing frame class rated corrent

Products Details

Product Description

The CJBF-63 6kA 10kA electronic residual current circuit breaker is designed by CEJIA engineers for stable operation, precise protection, short opening time, and a high breaking capacity index, all in one small device. The circuit breakers are also produced according to GB 10963 and IEC60898 standards. The circuit breakers are commonly installed for the overload protection of contactors, relays, and other electrical equipment. Main functions: short circuit protection, overload protection and isolation.

Machinery Parameter

  • High break capacity 10kA
  • Compact configuration, small size(2 standard dimensions)
  • Centrtc line off capacity, more safe and reliable
  • Duaf function connection terminal, Well connected
  • Contacts condition indicator easy to identify contact information
  • Up to 63A is available, wider current range
  • Matchable with many kinds of accessories, can be equipped with overvoltage protection

Notice Matters

The circuit breaker  should be wired according to the polarity marks, the positiveand negative polarities of power supply should be absolutely proper. Power incoming terminal of circuit breaker is “1” (1P) or “1,3” (2P), loadterminal is “2” (1P) or   “2” (positive  end  of  load), 4 ( negative end of load)(2P), don't make wrong connnection.

Order Guidelines

When placing an order, please give clear  indications on model, rated current value, tripping type, pole number and quantity of circuit breaker e.g: DAB7-63/DC miniature direct current  circuit  breaker, rated current is 63A tripping type is C, two-pole, C type 40A, 100 pieces, then it can be expressed as: CJBL-63/DC /2-C40100pcs.

Technical Data

Standard IEC61009/EN61009
Poles of number 1P+N/2P 3P+N/4P 2P 3P+N/4P
Rated current ln A 6-63A 6-32A 6-63A 40-63A
Rated voltacje(Ue) 230V/400V,50HZ
Rated current In 6-63A
Release features B,C,D features curves
Shell protection grade lP40( Afier instaiiation)
Ratedbreak capacity lcn 10kA(CJBL-40),6kA(CJBL-63)
Rated residual action current 10mA 30mA,50mA 100mA, 300mA
Maximum available fuse 100AgL( >10KA)
Climatic conditions resistance According  to IEC1008 in L standard
Total life 180000 times of operation
Lifespan No less than 6000 times on-offaction
No less than 12000 times on-off action
Release type Electronic type
Functions Protection against short circuit , leakage ,overload, over voltage,isolation
Type of residual current AC and A
Rated frequency f Hz 50-60Hz
Rated working voltage Ue VAC 230/400
Rated residual current I△n mA 10,30,100,300
Insulation voltage  Ui 500V
Rated impulse withstand voltage Uimp 6KV
Instantaneous tripping type B/C/D
Rated short circuit lcn(kA) CJBL-40 10KA,CJBL-63 6KA
Mechanical 12000
Electrical 6000
Protection degree IP40
Wire mm² 1~25
Working temperature (with daily average≤35℃) -5~+40℃
Resistance to humidity and heat Class 2
Altitude above sea ≤2000
Relative humidity +20℃,≤90%;+40℃,≤50%
Pollution degree 2
Installation environment Avoid obvious shock and vibration
Installation class Class II, Class III
Auxiliary contact
Alarm contact
ALT+AUX
Shunt release
Under voltage release -
Over voltage release

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours