CJN-1000 Transformer 1000W AC to DC Rail Type Single Output Switching Power Supply

CJN-1000 series is a 1000W single-group output closed power supply. lt adopts 85~264VAC full range AC input whole series to provide 5V,12V,15V,24V,36V and 48V output. ln addition to the efficiency of up to 91.5%, the design of the metal mesh enclosure enhances the heat dissipation capability, making the CJN-1000 more stable in harsh environments. It makes it easy for terminal systems to meet international energy requirements.CJN-1000 have complete protection functions ; it complies with TUVEN60950-1,EN60335-1,EN61558-1/-2-16,UL60950-1 and GB4943 international safety regulations, CJN-1000 series a cost-effective solution for a variety of industrial applications.

Products Details

Product Parameter

Type Technical indicators
Output DC voltage 12V 24V 36V 48V
Rated current 80A 40A 27.5A 20A
Rated power 960W 960W 990W 960W
Ripple and noise <150mV <150mV <240mV <240mV
Voltage regulation range ±10%
Voltage precision ±1.0%
Linear adjustment rate <±1%
Load regulation rate <±1.2% <±1% <±0.5% <±0.5%
Input Voltage range / frequency 180-264VAC 47Hz-63Hz 254VDC-370VDC
Efficiency (typical) >82% >84% >86% >86%
Working current 220VAC:9.5A
Shock current 60A 230VAC
Start up time 200ms、50ms、20ms:220VAC
Overload protection Type 105%-135% ; constant current output +V0 drop to underpressure point cut off output reset: power up again
Overvoltage protection ≥115%-145%Close the output
Protection characteristics Short circuit protection Close the output
Overtemperature protection RTH3: Fan often turn,≥90℃ Close the output
Environmental science Working temperature and humidity -10℃~+50℃;20%~90RH
working temperature and humidity -20℃ ~+85℃;10%~95RH
Security Pressure resistance Input-output: 1.5kvac input-case: 1.5kvac output-case:0.5kvac lasted for 1 minute
leakage current lnput-output 1.5KVAC<6mA;lnput-output 220VAC<1mA
lsolation resistance lnput-output and input - shell, output-shell: 500VDC/100mΩ
Other Size 291*132*68mm
Net weight / gross weight 2kg/2.1kg
Remarks (1) Measurement of ripple and noise: Using a 12"twisted-pair line with a capacitor of 0.1uF and 47uF in parallel at the terminal,the measurement is carried out at 20MHz bandwidth. (2)Efficiency is tested at the input voltage of 230VAC, rated load and 25℃ ambient temperature.Accuracy:including setting error,linear adjustment rate and load adjustmient rate.Test method of linear adjustment rate: testing from low voltage to high voltage at rated Load adjustment rate test method: from 0%-100% rated load.The start-up time is measured in the cold start state, and the fast frequent switch machine may increase the startup time.When the altitude is above 2000 meters, the operating temperature should be lowered by 5/1000.
     

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours