Type | Technical indicators |
Output | DC voltage | 5V | 12V | 24V | 36V | 48V |
Rated current | 18A | 8.5A | 4.5A | 2.8A | 2.3A |
Rated power | 90W | 102W | 108W | 100.8W | 110.4W |
Ripple and noise | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Voltage regulation range | ±10% |
Voltage precision | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load rregulation rate | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Star up time | 500ms、300ms/230VAC 500ms、30ms/115VAC(full load) |
Keep time | 55ms/230VAC 10ms/115VA(full load) |
Input | Voltage range/frequency | 85-264VAC/120-373VDC 47Hz-63Hz |
Efficiency(typcial) | 86% | 88% | 90% | 90.50% | 91% |
Working current | 1.9A/115VAC 1.2A/230VAC |
Shock current | Cold start:50A/230VAC |
Leakage current | <1mA 240VAC |
Protection characteristics | Overload protection | Protection type: burp mode, remove the abnormal situation and automatically return to normal |
Overvoltage protection | Protection type:close output and restart automatically to normal |
Environmental science | Working temperature and humidity | -30℃~+70℃;20%~90RH |
Storage temperature and humidity | -40℃~+85℃; 10%~95RH |
Security | Pressure resistance | Input - output :4KVAC input-case :2KVAC output -case: 1.25kvac duration :1 minute |
lnsulation impedance | Input - output and input - shell, output - shell: 500 VDC /100 m Ω 25℃,70% RH |
Other | Size | 129*97*30mm(L*W*H) |
Net weight / gross weight | 340g/365g |
Remarks | (1)Measurement of ripple and noise: Using a 12"twisted-pair line with a capacitor of 0.1uF and 47uF in parallel at the terminal,the measurement is carried out at 20MHz bandwidth. (2)Eificiency is tested at the input voltage of 230VAC,rated load and 25℃ ambient temperature.Accuracy: including setting error,linear adjustment rate and load adjustmient rate.Test method of linear adjustment rate: festing from low voltage to high voltage at rated load adjustment rate test method: from 0%-100% rated load.The start-up time is measured in the cold start state, and the fast frequent switch machine may increase the start up time.When the altitude is above 2o000 meters, the operating temperature should be lowered by 5/1000. |