DR-60-12 China Manufactory High Efficiency 60W DIN Rail SMPS Single Output Industrial Switching Power Supply

DR-30,45, 60 series is a 30, 45,60W single-group output closed power supply with 85-264VAC full range AC input. The entire series is available in 5V,12V,15V,24V,36V and 48V outputs. In addition to an eficiency of up to 91.5%, the metal mesh housing design enhances heat dissipation so that DR-30, 45, 60 operate in the temperature range of -30ºC to +70ºC without a fan . lt makes it easy for terminal systems to meet international energy requirements. DR-30,45,60 have complete protection; it complies with EN60950-1, EN60335-1, EN61558-1/-2-16 GB4943 international safety regulations, The DR-30, 45, 60series provide a cost-effective solution for a variety of industrial applications.

Products Details

Technical Data

Type Technical indicators
Output DC voltage 5V 12V 15V 24V
Ripple and noise <80mV <120mV <120mV <150mV
Voltage regulation range ±10%
Voltage precision ±2.0% ±1.0%
Linear adjustment rate <±1%
Input Start up time 100ms、30ms、21ms:110VAC/100ms、30ms、100ms:220VAC
Voltage range / frequency 85-264VAC 47Hz-63Hz(120VDC-370VDC)
Efficiency(typical) >78% >81% >83% >87%
Shock current 110VAC 20A.220VAC 40A
Protection characteristics Overload protection 105%-150% Type: Protection mode: burp mode automatic recovery after the abnormal condition is lifted.
Short circuit protection +VO The output abnormal condition will be restored automatically after it is removed
Environmental science Working temperature and humidity -10℃~+50℃;20%~90RH
Storage temperature and humidity -20℃~+85℃;10%~95RH
Security Pressure resistance Input-Output:3kvac lasted for 1 minute
Isolation resistance Input-Output and Input-shell,Output-shell: 500VDC/100MΩ
Other Size 78x93x56mm
Net weight / gross weight 270/290g
Remarks 1) Measurement of ripple and noise: Using a 12 "twisted-pair line with a capacitor of 0.1uF and 47uF in parallel at the terminal he measurement is carried out at 20MHz bandwidth.2)Efficiency is tested at the input voltage of 230VAC, rated load and 25℃  ambient temperature.Accuracy: including setting error, linear adiustment rate and load adjustment rate.Test method of linear adiustment rate: testing from low voltage to high voltage at rated Load adjustment rate test method: from 0%-100% rated load.The start-up time is measured in the cold start state, and the fast frequent switch machine may increase the startup time .When the altitude is above 2000 meters. the operatind temperature should be lowered by 5/1000.
 
Type DR-30
DC voltage 5V 12V 15V 24V
Rated current 3A 2A 2A 1.5A
Rated power 15W 24W 30W 36W
Load regulation rate ±1%
Working current <0.8A 110VAC <0.4A 220VAC
 
Type DR-45
DC voltage 5V 12V 15V 24V
Rated current 5A 3.5A 2.8A 2A
Rated power 25W 42W 42W 48W
Load regulation rate ±1%
Working current <1A 110VAC <0.5A 220VAC
 
Type DR-60
DC voltage 5V 12V 15V 24V
Rated current 6.5A 4.5A 4A 2.5A
Rated power 32.5W 54W 60W 60W
Load regulation rate ±1%
Working current <1.2A 110VAC <0.8A 220VAC
     

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours